The “Val1” Parameter on the Aritech 2X-F2 Fire Alarm Control Panel: How It Works and Why It Matters

How to Check the Real-Time Value of a Detector on the Aritech 2X-F2 Fire Alarm Panel

The Aritech 2X-F2 fire alarm control panel is known for its precision in real-time environmental monitoring. One of the most critical parameters on this panel is "Val1," which represents the reading level of detectors connected to the system. This article explains how the "Val1" parameter functions on the 2X-F2 model and how it can be interpreted to ensure safe and accurate monitoring.

Introduction to the "Val1" Parameter on the Aritech 2X-F2 Model

On the Aritech 2X-F2 fire alarm control panel, the "Val1" parameter provides an intensity metric for the sensor readings. These sensors monitor factors such as smoke presence, heat, or hazardous gases that could indicate the onset of a fire. The "Val1" value is continuously updated and displayed on the panel, enabling a detailed, real-time environmental analysis.

How the "Val1" Parameter Works and Is Interpreted

On the Aritech 2X-F2, the "Val1" parameter is displayed numerically for each detector, reflecting the concentration of particles or heat intensity, for example. This value is configurable and can be interpreted across three main levels:

  • Low Level: Indicates a safe condition, with no risk present.
  • Medium Level (Pre-Alarm): Suggests a slight change in conditions, which requires attention.
  • High Level (Alarm): Signals a risk situation that demands immediate action.

How to Check the Real-Time Value of a Specific Detector

The Aritech 2X-F2 panel allows the operator to view the updated value of each detector in real-time, which facilitates monitoring and decision-making. To check the value of a specific detector:

1. Access the Main Menu: Press F4 to enter the Menu.

2. Enter "Reports": In the reports section, search for "Device Status" and select the desired Loop.

3. View the Real-Time Value: Using the rotary button, browse the device list for the desired device and press the rotary button to view its value.

For a practical and visual demonstration of this process, refer to the following video, where I show how to access and check the real-time value on the Aritech 2X-F2 panel. In this case, I verified the values for devices 67, 68, 69, 70, and 71 on Loop 3.

Advantages of Monitoring the "Val1" Parameter on the 2X-F2

Monitoring the "Val1" parameter on the Aritech 2X-F2 offers several benefits, including:

  • Constant Monitoring: Provides continuous readings of environmental conditions.
  • Reduction of False Alarms: Accurate configuration reduces unnecessary alarms in dynamic environments.
  • Early Response: The pre-alarm feature allows for preventive action before a critical situation arises.
  • Remote Diagnostics: The ability to monitor values remotely improves the overall safety of the system.

The "Val1" parameter on the Aritech 2X-F2 control panel is essential for effective and safe monitoring. With a configuration tailored to the specific needs of the site, this parameter enables a clear distinction between real alert situations and normal environmental variations. By using the demonstration video, viewers can better understand the importance and access method for this feature on the 2X-F2 panel.

Complete Guide to KNX Datapoint Types: Everything ...
AxTraxNG: The Complete Solution for Access Control...
 

Comments

No comments made yet. Be the first to submit a comment
Already Registered? Login Here
Monday, 21 April 2025